DES-4122 Free Specialist – Implementation Engineer PowerEdge Version 2.0 Exam Questions and Answers

Share Specialist – Implementation Engineer PowerEdge Version 2.0 exam questions and answers online for free from Lead4Pass DES-4122 dumps: https://www.leads4pass.com/des-4122.html (60 Q&A).

Lead4Pass DES-4122 is updated 1-2 times a month to ensure real-time effectiveness! You can download the latest Specialist – Implementation Engineer PowerEdge Version 2.0 exam questions and answers at any time, and provide PDF and VCE learning formats to help you practice easily and efficiently.

Download DES-4122 Free Specialist – Implementation Engineer PowerEdge Version 2.0 Exam Questions and Answers Online: https://drive.google.com/file/d/13roP7MeoC5xfnHaBpfKp-_lJEOwKdvKG/

Practice DES-4122 Free Specialist – Implementation Engineer PowerEdge Version 2.0 Exam Questions and Answers Online

FromNumber of exam questionsExam nameExam code
Lead4Pass15Specialist – Implementation Engineer PowerEdge Version 2.0DES-4122
Question 1:

What is the requirement to operate GPUs in a Dell EMC PowerEdge R740 server?

A. All GPU cards must be installed at the same time

B. All GPU cards must be of the same type but can be a different model

C. All GPU cards must be of the same type and model

D. All GPU cards must be installed on the same riser card.

Correct Answer: A

Question 2:

You are creating a new RAID 5 storage pool on a Dell EMC PowerEdge server based on 30 x 1TB drives Which PERC model best supports this configuration?

A. S140

B. H740P

C. H740T

D. H330

Correct Answer: A

Question 3:

What is the Open Compute Project (OCP) card used for in a Dell EMC PowerEdge server?

A. Flexibility to choose interconnects

B. Fixed networking card

C. Consume a PCIe slot

D. Provide a hot-swap component

Correct Answer: B

Question 4:

Dell EMC PowerEdge 14G servers support which technology?

A. Quicksync 1.0

B. Intel Boot Guard

C. AMD GuardMI

D. iDRAC8

Correct Answer: C

Question 5:

How can a technician know whether IDRAC9 System Lockdown mode is enabled?

A. Lockdown activation message in the red box in the iDRAC web GUI Access to LCC is disabled when the server boots

B. Lockdown activation message in the red box in the iDRAC web GUI Access to LCC requires a password when the server boots

C. Lockdown activation message in the yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots

D. Lockdown activation message in the yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots

Correct Answer: A

Question 6:

CORRECT TEXT

For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.

When you have finished using the simulator, click Next.

des-4122 exam questions 6

A. No answer

B. Place Holder

C. Place Holder

D. Place Holder

Correct Answer: A

Question 7:

DRAG DROP

Refer to the exhibit.

des-4122 exam questions 7

Match each callout to the Dell EMC PowerEdge server model shown.

Select and Place:

des-4122 exam questions 7-1

Correct Answer:

des-4122 exam answers 7

Question 8:

Which rear disk drive option is available in a Dell EMC PowerEdge R740xd server?

A. 4x 3.5″ drives

B. 2×3.5″ drives

C. 8×2 5″ drives

D. 6×2 5″ drives

Correct Answer: B

Question 9:

DRAG DROP

Match each RAID level to its characteristic.

Select and Place:

des-4122 exam questions 9

Correct Answer:

des-4122 exam answers 9

Question 10:

A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned

How should the technician obtain access to the remaining 2 TB (approximately) of storage?

A. Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server

B. Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB

C. Upgrade to a newer version of the operating system

D. Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again

Correct Answer: C

Question 11:

Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

A. 11G

B. 12G

C. 13G

D. 14G

Correct Answer: D

Question 12:

A Dell EMC PowerEdge server logs the following CPU Machine Check error CPU1 IERR What action might solve the problem?

A. Remove flea power

B. Update the Intel driver

C. Reseat the IDSDM

D. Swap the PERC controller

Correct Answer: B

Question 13:

A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:

1.

2x CPUs

2.

384 GB RAM

3.

6x 1 TB drives

4.

1x PSU

The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed

How can the technician upgrade the license?

A. The license cannot be upgraded on a single PSU system

B. Power on the server, then connect to the iDRAC and upgrade the iDRAC license before powering down the server

C. The license cannot be upgraded because the user will not allow the server to be powered on

D. Connect to the iDRAC GUI and upgrade the.DRAC license while the server .s powered down

Correct Answer: A

Question 14:

An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to a dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.

What should the engineer do to complete the task?

A. Add the PowerEdge R420 PSU modules to the PowerEdge R440

B. Order a new PSU specific to the existing PowerEdge R440

C. Add the PowerEdge R430 PSU modules to the PowerEdge R440

D. Configure the PowerEdge R440 PSU with a 1+1 configuration

Correct Answer: A

Question 15:

DRAG DROP

Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.

Select and Place:

des-4122 exam questions 15

Correct Answer:

des-4122 exam answers 15

Now! Download the latest and complete Specialist – Implementation Engineer PowerEdge Version 2.0 exam questions and answers for DES-4122: https://www.leads4pass.com/des-4122.html (60 Q&A), to help you pass the exam 100% successfully.

Related Posts